Search results for "optical tomography"
showing 7 items of 7 documents
Radon transform as a set of probability distributions
2009
It is proved that the Radon transform of the Wigner function gives the probability distributions related to measuring the observable operators obtained as linear combinations of position and momentum of the relevant particle. The generalization to an arbitrary number of degrees of freedom is given.
Novel GTA-PVA Fricke gels for three-dimensional dose mapping in radiotherapy
2017
Abstract One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiation-sensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels). These formulations suffer from spontaneous-oxidation and diffusion of ferric ions after irradiation; chelating agents such as xylenol-orange significantly reduces the latter. Other gel types consist of dispersed monomers, and rely on radiation-induced cros…
A comparison of three different micro-tomography systems for accurate determination of microvascular parameters
2008
The investigation of micro-vessel dimensions in 3D is currently problematic due to their complex structures and fine scale. Quantification of vascular parameters is important in several fields of biomedicine; including embryogenesis, wound healing, diseases characterized by uncontrolled angiogenesis (e.g. tumor growth and metastasis) and the development of implantable bio-materials where a functional vascular supply is critical to their successful integration into host tissue. However, techniques that can resolve the micron-scaled features of these capillary beds, such as scanning electron and confocal microscopy, do not allow for total image reconstitution in 3 D in thick tissue samples [1…
The measuring method for tests of horizontal two-phase gas–liquid flows, using optical and capacitance tomography
2009
Abstract The paper presents a measurement method in testing horizontal two-phase gas–liquid flows. It also describes the test stand including two tomography measurement systems. The optical and capacitance tomography systems can be used for measurements at the same time. It is necessary to apply two tomography systems working at the same time because of complexity of phenomena occurring in two-phase flows, and a wide range of applicability of the presented method. The optical tomography system in which a tested object is illuminated from five projections. The measurement of luminous intensity is changed into a discrete signal (0 or 1) in the detectors including 64 optical sensors. Next, the…
Application of optical tomography for measurements of aeration parameters in large water tanks
2003
The paper presents a design and application study of a prototype optical tomograph for the detection and definition of shapes of gas bubbles moving in a liquid. In the applied method of measurements, the column is exposed to a homogeneous light beam and next the ray is detected with the use of optical waveguided detectors. Spatial reconstruction of the bubble shapes is done on the basis of the signals coming from two perpendicular systems of detectors. The bubble shape is approximated by an ellipsoid with suitably determined semi-axes and with the use of genetic algorithms based on the neuron network. Influence of the structure and dynamics of the measuring path on errors in representation …
Optical tomography from focus
2007
A model and a method providing a 3D reconstruction of a given translucent object from a series of image acquisitions performed with various focus tunings is proposed. The object is imaged by transmission; refraction, reflection and diffusion effects are neglected. It is modeled as a stack of translucent parallel slices and the acquisition process can be described by a set of linear equations. We propose an efficient inversion technique with O(n) complexity, allowing practical applications with a simple laptop computer in a very reasonable time. Examples of results obtained with a simulated 3D translucent object are presented and discussed.
Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry
2021
Radiation-sensitive gels are among the most recent and promising developments for radiation therapy (RT) dosimetry. RT dosimetry has the twofold goal of ensuring the quality of the treatment and the radiation protection of the patient. Benchmark dosimetry for acceptance testing and commissioning of RT systems is still based on ionization chambers. However, even the smallest chambers cannot resolve the steep dose gradients of up to 30–50% per mm generated with the most advanced techniques. While a multitude of systems based, e.g., on luminescence, silicon diodes and radiochromic materials have been developed, they do not allow the truly continuous 3D dose measurements offered by radiation-se…